Dr.G.K.Kumar, Dr.S.Sridhar, Laryngeal Mask Airway cuff pressure application during general anaesthesia – Instrumental versus conventional method – A comparative study., INDIAN JOURNAL OF APPLIED RESEARCH : Volume-8 | Issue-6 | June-2018
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:50%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><b><span style="font–size:16.0pt;line–height:50%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">Objective:</span></b><b><span style="font–size:17.0pt;line–height:50%;font–family:"Calibri Light","sans–serif";
mso–fareast–font–family:"Calibri Light";mso–bidi–font–family:"Calibri Light";
letter–spacing:0pt"><o:p></o:p></span></b></h3>
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:107%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><span style="font–size:13.0pt;line–height:107%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">To evaluate the conventional practice ofLaryngeal Mask Airway <span style="mso–spacerun:yes"> </span>(LMA) cuff inflation and pressure measurement as compared to the instrumental method.<o:p></o:p></span></h3>
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:107%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><b><span style="font–size:16.0pt;line–height:107%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">Study Design:<o:p></o:p></span></b></h3>
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:107%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><span style="font–size:13.0pt;line–height:107%">Prospective observational study.</span><span style="font–size:13.0pt;line–height:107%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt"><o:p></o:p></span></h3>
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:50%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><b><span style="font–size:16.0pt;line–height:50%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">Place and Duration of Study:</span></b><span style="font–size:17.0pt;line–height:50%;font–family:"Calibri Light","sans–serif";
mso–fareast–font–family:"Calibri Light";mso–bidi–font–family:"Calibri Light";
letter–spacing:0pt"><o:p></o:p></span></h3>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><span style="font–size:13.0pt">Aakash Fertility Centre, 10, Jawaharlal Nehru Road , Vadapalani , Chennai, during the period of<span style="mso–spacerun:yes"> </span>August 2016 – July 2017<o:p></o:p></span></p>
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:50%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><b><span style="font–size:16.0pt;line–height:50%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">Methods:</span></b><span style="font–size:17.0pt;line–height:50%;font–family:"Calibri Light","sans–serif";
mso–fareast–font–family:"Calibri Light";mso–bidi–font–family:"Calibri Light";
letter–spacing:0pt"><o:p></o:p></span></h3>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><span style="font–size:13.0pt">A total of 200 adult female patients<span style="mso–spacerun:yes"> </span>posted for hysteroscopic surgery under General Anaesthesia for infertility treatment were selected for this study. Patients with anticipated difficult intubation, risk for aspiration, known anatomical laryngotracheal abnormalities, and emergency cases were excluded. Allselected patients were inserted<span style="mso–spacerun:yes"> </span>with size 4. The LMA cuff inflated with25 ml by a qualified anaesthesia technician. Cuff pressures were measured using aneroid manometer. LMA cuff pressure of 50–60 cm of water was considered as standard.<o:p></o:p></span></p>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><b><span style="font–size:16.0pt;font–family:
"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light"">Results:</span></b><span style="font–size:13.0pt"><o:p></o:p></span></p>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><span style="font–size:13.0pt">In 85% of the patients, the cuff pressure measurements were above the standard. The mean cuff pressure was 88 cm of water. <o:p></o:p></span></p>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><b><span style="font–size:16.0pt">Conclusion:</span></b><span style="font–size:13.0pt"><o:p></o:p></span></p>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><span style="font–size:13.0pt">The conventional method for LMA cuff inflation and pressure measuring is unreliable. A routine instrumental cuff pressure, monitoring is suggested.<o:p></o:p></span></p>
Keywords: Cuff pressure, LMA, measurement