Original Research Paper Anesthesiology

Endotracheal tube cuff pressure application during general anaesthesia – Instrumental versus conventional method – A comparative study.

Dr.G.K.Kumar Dr.S.Sridhar

Abstract

<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:50%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><b><span style="font–size:16.0pt;line–height:50%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">Objective:</span></b><b><span style="font–size:17.0pt;line–height:50%;font–family:"Calibri Light","sans–serif";
mso–fareast–font–family:"Calibri Light";mso–bidi–font–family:"Calibri Light";
letter–spacing:0pt"><o:p></o:p></span></b></h3>
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:107%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><span style="font–size:13.0pt;line–height:107%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">To evaluate the conventional practice of endotracheal tube (ETT) cuff inflation and pressure measurement as compared to the instrumental method.<o:p></o:p></span></h3>
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:50%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><b><span style="font–size:16.0pt;line–height:50%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">Study Design:</span></b><span style="font–size:16.0pt;line–height:50%;font–family:"Calibri Light","sans–serif";
mso–fareast–font–family:"Calibri Light";mso–bidi–font–family:"Calibri Light";
letter–spacing:0pt"><o:p></o:p></span></h3>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><span style="font–size:13.0pt">Prospective observational study.<o:p></o:p></span></p>
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:50%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><b><span style="font–size:16.0pt;line–height:50%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">Place and Duration of Study:</span></b><span style="font–size:17.0pt;line–height:50%;font–family:
"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt"><o:p></o:p></span></h3>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><span style="font–size:13.0pt">Aakash Fertility Centre, 10, Jawaharlal Nehru Road ,Vadapalani , Chennai, during the period of<span style="mso–spacerun:yes"> </span>August 2016 – July 2017<o:p></o:p></span></p>
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:50%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><b><span style="font–size:16.0pt;line–height:50%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">Methods:</span></b><span style="font–size:17.0pt;line–height:50%;font–family:"Calibri Light","sans–serif";
mso–fareast–font–family:"Calibri Light";mso–bidi–font–family:"Calibri Light";
letter–spacing:0pt"><o:p></o:p></span></h3>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><span style="font–size:13.0pt">A total of 200 adult female patients<span style="mso–spacerun:yes"> </span>posted for diagnostic laparoscopic surgery under General Anaesthesia for infertility treatment were selected for this study. Patients with anticipated difficult intubation, risk for aspiration, known anatomical laryngotracheal abnormalities, and emergency cases were excluded. Trachea was intubated with size 7.0 mm. The ETT cuff was inflated with air by one of the anaesthesia technician. Cuff pressures were measured using aneroid manometer. ETT cuff pressure of 20–30 cm of water was considered as standard.<o:p></o:p></span></p>
<h3 style="margin–top:16.0pt;margin–right:0in;margin–bottom:0in;margin–left:
0in;margin–bottom:.0001pt;line–height:50%;mso–pagination:widow–orphan lines–together;
background:white;border:none;mso–padding–alt:31.0pt 31.0pt 31.0pt 31.0pt;
mso–border–shadow:yes"><b><span style="font–size:16.0pt;line–height:50%;
font–family:"Calibri Light","sans–serif";mso–fareast–font–family:"Calibri Light";
mso–bidi–font–family:"Calibri Light";letter–spacing:0pt">Results:</span></b><span style="font–size:16.0pt;line–height:50%;font–family:"Calibri Light","sans–serif";
mso–fareast–font–family:"Calibri Light";mso–bidi–font–family:"Calibri Light";
letter–spacing:0pt"><o:p></o:p></span></h3>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><span style="font–size:13.0pt">In 87% of the patients, the cuff pressure measurements were above the standard. The mean cuff pressure was 46 cm of water. <o:p></o:p></span></p>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;line–height:50%;background:white"><b><span style="font–size:
16.0pt;line–height:50%">Conclusion:</span></b><span style="font–size:16.0pt;
line–height:50%"><o:p></o:p></span></p>
<p class="p" style="margin–top:10.5pt;margin–right:0in;margin–bottom:10.5pt;
margin–left:0in;background:white"><span style="font–size:13.0pt">The conventional method for ETT cuff inflation and pressure measuring is unreliable. A routine instrumental cuff pressure, monitoring is suggested.<o:p></o:p></span></p>

Keywords: Cuff pressure, endotracheal tube, measurement