Sankhe Dakshata Dinesh, Tella Manisha Choudary, Deosarkar Bharat Anantrao, A comparative evaluation of efficacy of five different procedures in elimination of biological debris on rotary endodontic instruments before sterilization– An in–vitro stereomicroscopic study., INDIAN JOURNAL OF APPLIED RESEARCH : Volume-8 | Issue-6 | June-2018
<p class="MsoNormal" style="line–height:150%"><b style="mso–bidi–font–weight:
normal"><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif"">Aim</span></b><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif"">– this study was done to evaluate the efficacy of five different procedures on elimination of biological debris on rotary endodontic instruments before sterilization.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:150%"><b style="mso–bidi–font–weight:
normal"><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif"">Materials and Method</span></b><span style="font–size:14.0pt;line–height:150%;font–family:
"Times New Roman","serif"">– totally twenty–five rotary endodontic files after clinical use for cleaning and shaping were taken in the study. They were divided into five groups each containing five files in accordance with various cleaning procedures used. Detection of debris on files was done using rhodamine B stain with the help of stereomicroscope.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:150%"><b style="mso–bidi–font–weight:
normal"><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif"">Statistical analysis used</span></b><span style="font–size:14.0pt;line–height:150%;
font–family:"Times New Roman","serif"">:results were analyzed using Kruskal–Wallis Chi– Square test.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:150%"><b style="mso–bidi–font–weight:
normal"><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif"">Results</span></b><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif"">:the mean value of maximum biological contamination was highest in Group 2(files immersed in 2% glutaraldehyde solution) and lowest in group 5(files which were cleaned using brush).<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:150%"><b style="mso–bidi–font–weight:
normal"><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif"">Conclusions</span></b><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif"">: endodontic instrument which were cleaned manually using nylon brush were found to be more efficient.<o:p></o:p></span></p>
Keywords: pre–cleaning, rotary endodontic instruments, biological debris, cross–infection