Dr Sumesh T. Rao, Dr Vikas Gowda, Dr Rakesh Reddy V Hyomental Distance Ratio as a Diagnostic Predictor of Difficult Laryngoscopy Indian Journal of Applied Research, Vol.III, Issue.VIII August 2013
Purpose: This study has been done to evaluate the usefulness of the Hyomental Distance Ratio (HMDR) for
accurately predicting difficult visualization of the larynx (DVL) in apparently normal patients in comparison
with other predictors.
Methods: 198 apparently normal patients of more than 18 years of age, with ASA I and II, undergoing general anesthesia
with tracheal intubation were evaluated. A hard–plastic bond ruler is used to measure the distance from the tip to the
anterior–most part of the mentum was measured and defined as the Hyomental distance. After induction using thiopentone
and paralysis using suxamethonium, glottic visualisation was assessed by using modified Cormach and Lehane classification
without external laryngeal manipulation
Results: The sensitivity of HMDR for predicting Difficult Laryngoscopy was 27.78% and specificity was 98.89%. The test has
a positive predictive value of 71.43% , Negative predictive value of 93.19%
Conclusion: HMDR is a clinically reliable predictor of DVL to certain extent because of its high specificity and negative
predictive value. Seeking an optimal combination of tests that includes the HMDR and other predictors is recommended.
Keywords: Hyomental Distance Ratio, Predicting Difficult Laryngoscopy