Drashti V. Kapadia Comparison of % Cod Removal With Rule Based Fuzzy Approach In Activated Sludge Process at Gajrawadi Sewage Treatment Plant Indian Journal of Applied Research, Vol.5, Issue : 1 January 2015
Activated sludge process is the important unit in Municipal Sewage treatment plant (stp) with basic parameters
of mlss and aeration time. From data collection of year 2008 and 2009 for Gajrawadistp and
consideringmlss and aeration time as an input parameters, to get % cod removal as an output parameter. Results are
generated with the help of matlab software using fuzzy approach.The output value of %cod removal obtained same
values with very minor deviation. Results are analyzed and compared with laboratory analysis.
Keywords: aeration time, cod, mlss, stp