Original Research Paper Medical Science

Diagnostic Peritoneal Lavage by Blunt Tip Trocar(5mm) Channeled Drain Technique–A Case Series

Dr.Kamlesh A Bhadreshwara Dr.Alpesh Amin

Abstract

Diagnostic peritoneal lavage (DPL) is an invasive, rapid and highly accurate test for evaluating intraperitoneal
hemorrhage or a ruptured hollow viscus. DPL plays a role in both blunt and penetrating abdominal
trauma. In this article we are introducing a simple technique that can even speed up the DPL procedure by using blunt
tip 5 mm trocar – 15 French Blake silicon drain in a semi–open technique. Method: Semi–open DPL was performed
in 11 patients with blunt abdominal trauma (BAT). A blunt tip 5 mm trocar was introduced into the peritoneal cavity
blindly and 15 Fr size Blake channeled drain was advanced into the peritoneal cavity and the peritoneal effluent
was withdrawn and analyzed. Results: A total of 11 blunt abdominal trauma patients were subjected to 5mm Blunt
Tip Trocar–Channeled Drain DPL technique. The DPL was grossly positive in 9 patients (81.8%) and subsequently were
managed surgically and in two patients (18.2%) it was grossly and microscopically negative, subsequently both were
managed conservatively. There was no complications attributed to this new DPL technique. Conclusion: The preliminary
data suggest that blunt tip 5mm trocar – Channeled Drain technique delivers a faster reliable way of performing DPL in
trauma patients. However, large number of cases is needed to justify its Routine use in trauma.