line–height:200%;font–family:"Arial","sans–serif"">BACKGROUND AND PURPOSE: We undertook a prospective clinical trial assessing the Nanos® short stem cementless femoral prosthesis. The primary objective was to assess the implant for subsidence and rotational stability via Radiostereometric Analysis (RSA).<span style="mso–spacerun:yes"> </span>The secondary objective was to assess functional outcome.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–top:0in;margin–right:–24.45pt;margin–bottom:
0in;margin–left:–7.1pt;margin–bottom:.0001pt;text–align:justify;text–justify:
inter–ideograph;line–height:200%"><span lang="EN–AU" style="font–size:11.0pt;
line–height:200%;font–family:"Arial","sans–serif"">PATIENTS AND METHODS: 28 patients undergoing unilateral Total Hip Arthroplasty (THA) using ashort stem prosthesis were compared to a control group using a standard<span style="color:black">Corail® stem</span>.Both stems were uncemented and the procedures performed by the same surgeons. Data collection points were preoperative, 3 months and 2 years post operatively. RSA radiographs were performed to assess subsidence and rotational stability.<span style="mso–spacerun:yes"> </span>Functional analysis was undertaken using the Oxford Hip Score (OHS).<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–top:0in;margin–right:–24.45pt;margin–bottom:
0in;margin–left:–7.1pt;margin–bottom:.0001pt;text–align:justify;text–justify:
inter–ideograph;line–height:200%"><span lang="EN–AU" style="font–size:11.0pt;
line–height:200%;font–family:"Arial","sans–serif"">RESULTS: Theshortstem showed a median subsidence of 0.12mm at 3 months witha further 0.09mm in the 3–24 month interval.Medianposterior translation of prosthesis head (retroversion) was 0.21mm at 3 months, with a further 0.07mm in the 3–24 month interval. Varus/valgus displacements measured were minimal. The mean OHS improved from 23 preoperatively to 44 at 3 months and 43 at 24 months review. There were 2 early revisions: one for leg length discrepancy and one for early loosening secondary to under–sizing of the implant. There were no significant differences to the control group.<span style="color:#0000F7"><o:p></o:p></span></span></p>
<p class="MsoNormal" style="margin–top:0in;margin–right:–24.45pt;margin–bottom:
0in;margin–left:–7.1pt;margin–bottom:.0001pt;text–align:justify;text–justify:
inter–ideograph;line–height:200%"><span lang="EN–AU" style="font–size:11.0pt;
line–height:200%;font–family:"Arial","sans–serif"">INTERPRETATION: THA patients with this stem demonstrated good stability and excellent short–term functional results, however the high revision rate in our series remains a concern.<i style="mso–bidi–font–style:normal"><o:p></o:p></i></span></p>