Dr Rajendra Wamanrao Baitule, Dr Sanjeev V Jaiswal, Dr Ankur Chawla, Complex fracture distal end radius managed by dynamic external fixator., PARIPEX‾INDIAN JOURNAL OF RESEARCH : Volume-7 | Issue-9 | September-2018
<p class="MsoNormal" style="line–height:normal"><b style="mso–bidi–font–weight:
normal"><span style="font–size:12.0pt;mso–bidi–font–family:Arial">Background:–</span></b><span style="font–size:12.0pt;font–family:"Times New Roman","serif"">Distal radius fractures represents most common fractures of all fracture. Distal radius fractures in the elderly may represent an insufficiency fracture associated with all of the risk factors for osteoporosis</span><span style="font–size:
12.0pt;mso–bidi–font–family:Arial">.</span><span style="font–size:12.0pt">The external fixator are mechanical efficient in complex intraarticularfractutre management, its capacity for fracture adjustment during healing period.</span><span style="font–size:12.0pt;mso–bidi–font–family:Arial"><o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:normal"><b style="mso–bidi–font–weight:
normal"><span style="font–size:12.0pt;mso–fareast–font–family:"Times New Roman";
mso–bidi–font–family:Arial">Material and Method:–</span></b><span style="font–size:12.0pt;font–family:"Times New Roman","serif"">All fractures were classified according to AO classification b and c. Baseline demographics and injury characteristics were recorded. In this study of 30 patients, 19 sustained type 23 b fracture, 11 had type 23 c<span style="mso–spacerun:yes"> </span>fracture.All patients were managed by external fixator.</span><span style="font–size:12.0pt"><o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:115%"><b style="mso–bidi–font–weight:
normal"><span lang="EN–IN" style="font–size:12.0pt;line–height:115%;mso–ansi–language:
EN–IN">Result:–</span></b><span style="font–size:12.0pt;line–height:115%;
font–family:"Times New Roman","serif"">This study achieved excellent results in 20 patients, good in 6 patients, fair in 2 patients, poor in 2 patients evaluated as per the criteria suggested by Green and O’Brien Score (Cooney modification). (fig1)In this study, 8 pt had wrist pain and stiffness and 6 pt<span style="mso–spacerun:yes"> </span>had finger stiffness as their post operative complication. Pain and stiffness in wrist and finger stiffness significantly improved after physiotherapy.<o:p></o:p></span></p>
<p class="Default" style="line–height:115%">Our case series attributes to 88% of excellent to good results and 12% of fair to poor results. Thus, it suggests that ligamentotaxis plays a good role in anatomic restoration in unstable fractures as well as intra articular fractures.</p>
<p class="MsoNormal" style="line–height:normal"><span lang="EN–IN" style="font–size:12.0pt;mso–ansi–language:EN–IN"><o:p> </o:p></span></p>
<p class="Default" style="line–height:115%"><b><span lang="EN–IN" style="mso–fareast–font–family:
"Times New Roman";mso–bidi–font–family:Arial;mso–ansi–language:EN–IN">Conclusion:–</span></b></p>
<p class="Default" style="line–height:115%">1)The external fixator are mechanical efficient in complex intraarticularfractutre management, its capacity for fracture adjustment during healing period.<b style="mso–bidi–font–weight:normal"><o:p></o:p></b></p>
<p class="Default" style="line–height:115%">2)External fixator is easy and safe to use even under regional anesthesia.</p>
<p class="Default" style="line–height:115%">3)External fixator is simple device for fracture fixation with preservation of<span style="mso–spacerun:yes"> </span>fracture haematoma.</p>
<p class="Default" style="line–height:115%">4)Shorter period of surgery with minimal exposure no need of torniquet</p>
<p class="Default" style="line–height:115%">5)Minimum instrumentation and less expertise required</p>
<p class="Default" style="line–height:115%">6)Use of dynamic external fixator in complex intraarticular fracture of distal end radius effective method of treatment. Of fracture using principle of ligamentotaxis</p>
Keywords: Fracture distal end of radius, Ligamentotaxis, External fixator