Original Research Paper Pediatrics

PATTERN OF CONGENITAL HEART DISEASE IN NEONATAL CARE UNIT IN TERTIARY CARE HOSPITAL

Dr PANKAJ KUMAR SINGHAL Dr SHWETA GOYAL

Abstract

<p> </p>
<p class="MsoNormal"><b><i><span style="font–size:12.0pt;line–height:115%;
font–family:"Times New Roman","serif"">Objective(s)</span></i></b><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:
115%;font–family:"Times New Roman","serif"">: </span></b><span style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Pattern of congenital heart disease in neonatal care unit in tertiary care hospital<b style="mso–bidi–font–weight:normal"><u><o:p></o:p></u></b></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
normal;mso–layout–grid–align:none;text–autospace:none"><b><i><span style="font–size:12.0pt;font–family:"Times New Roman","serif"">Method(s):</span></i></b><span style="font–size:12.0pt;font–family:"Times New Roman","serif""> This is a retrospective hospital based study carried out over a period of 12 months<span style="mso–spacerun:yes"> </span><span style="mso–spacerun:yes"> </span>( August 2017– July 2018) where all suspected case of CHD <span style="mso–spacerun:yes"> </span>due to the appearance of murmur, cyanosis, tachycardia were subjected to echocardiographic study. The age, sex, clinical presentation and echo findings were well documented.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
normal;mso–layout–grid–align:none;text–autospace:none"><span style="font–size:
12.0pt;font–family:"Times New Roman","serif";color:#231F20"><span style="mso–spacerun:yes"> </span><o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
normal;mso–layout–grid–align:none;text–autospace:none"><b><i><span style="font–size:12.0pt;font–family:"Times New Roman","serif"">Observation(s) :</span></i></b><span style="font–size:12.0pt;font–family:"Times New Roman","serif""> A total of 214(5.3%) <span style="mso–spacerun:yes"> </span>patients were suspected as having congenital heart disease<span style="mso–spacerun:yes"> </span>out of<span style="mso–spacerun:yes"> </span>4020 . On Echocardiography 93 (prevalence of 20.6/1000neonates) were found to be having significant findings. About 77 (82.7%) were the acyanotics,<span style="mso–spacerun:yes"> </span>and 16 (17.20%) were cyanotic heart patients.<span style="mso–spacerun:yes"> </span>Among the acyanotic heart diseases atrial septal defect was the most frequent lesion seen in 29% , followed by <span style="mso–spacerun:yes"> </span>VSD (27%) ,<span style="mso–spacerun:yes"> </span>patent ductus arteriosus<span style="mso–spacerun:yes"> </span>in 20% neonates. Among the cyanotic heart diseases tetralogy of Fallot (12.5%) <span style="mso–spacerun:yes"> </span>was the most frequent cyanotic heart disease seen in patients</span><span style="font–size:12.0pt;font–family:BookAntiqua;mso–bidi–font–family:BookAntiqua">.</span><span style="font–size:12.0pt;font–family:"Times New Roman","serif""><o:p></o:p></span></p>
<p class="MsoNormal" style="margin–top:10.0pt;text–align:justify;line–height:
normal"><b><i><span style="font–size:12.0pt;font–family:"Times New Roman","serif"">Conclusion(s):</span></i></b><span style="font–size:12.0pt"> </span><span style="font–size:12.0pt;font–family:
"Times New Roman","serif"">In this era of most accurate diagnostic modalities, any clinical suspicion of congenital heart disease should be confirmed by echocardiography to hasten the diagnosis, timely management and prevention of complications.<o:p></o:p></span></p>

Keywords: Neonates, congenital–heart disease, echocardiography, prevalence, Patent ductus arteriosus