Sachdeva Puneet, Dr Gagandeep Kaur, Basu Sabita, Tahlan Anita, Assessment of machine related factors affecting platelet yield in single donor platelets, PARIPEX‾INDIAN JOURNAL OF RESEARCH : Volume-7 | Issue-3 | March-2018
<p> </p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%;mso–layout–grid–align:none;text–autospace:none"><b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Background: </span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman","serif"">The quality of single donor platelets (SDP) in terms of yield influences the platelet recovery in the recipient. Various machine/procedure related factors such as volume of whole blood processed and time taken for the procedure may affect platelet yield. <o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%;mso–layout–grid–align:none;text–autospace:none"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">Aim: </span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">The aim of present study was to assess the effect of various machine/procedure related factors on platelet yield.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%;mso–layout–grid–align:none;text–autospace:none"><b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Materials and methods</span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:
200%;font–family:"Times New Roman","serif"">: A total of 171 plateletpheresis procedures performed using continuous flow cell separator (Amicus Automated Blood Collection System version 2.52/3.1) were evaluated for platelet yield.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%;mso–layout–grid–align:none;text–autospace:none"><b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Results</span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">: The mean platelet yield was 3.8 + 1.65 X 10<sup>11</sup> /unit. Platelet yield correlated positively with total whole blood processed (r=0.503; p < 0.001), time taken for the procedure (r = 0.284; p < 0.001) and ACD used (r = 0.519; p < 0.001). No correlation was observed between MIR and platelet yield (r = 0.101; p = 0.248).<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%;mso–layout–grid–align:none;text–autospace:none"><b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Conclusion: </span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman","serif"">Appropriate importance should be given to various machine/procedure related factors during the plateletpheresis procedure to have improved product quality.<o:p></o:p></span></p>
Keywords: Plateletpheresis, machine/procedure related parameters, cell separator, platelet yield