Bharathi sukumar, Ramasamy Periyapatti Periyasamy, Sivakumar, Uma Maheswari, Thiriveni Balajji, A study on systemic effects of Chromium among construction workers with contact dermatoses attending tertiary care hospital in Coimbatore., PARIPEX‾INDIAN JOURNAL OF RESEARCH : Volume-7 | Issue-5 | May-2018
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal">AIM: </b>To elicit the systemic effects and correlate with urinary and serum chromium levels among constructionworkers who presented with contact dermatitis.<b style="mso–bidi–font–weight:
normal">MATERIALS AND METHODS: </b>This was a prospective observational hospital– based clinical study, conducted among 50construction workers who presented with skin and systemic manifestations to the our OPD Dermatology from Oct2016 to Jan2017.The data containing<span style="color:black;background:white"> demographic details, occupational details, clinical manifestation,systemic examination and co morbidities </span>were collected.<span style="color:black;
background:white">All routine and special investigations including, </span>Urine routine, Hematological profile with Peripheral smear, Blood sugar, LFT,<span style="mso–spacerun:yes"> </span>Serum Electrolytes,<span style="mso–spacerun:yes"> </span>Blood urea creatinine,<span style="color:
black;background:white">TFT</span>, Lipid profile, Chest X ray,USGabdomen, ECG, Spirometry were done. Chromium levels in blood and urine were analyzed separately <span style="color:black;background:white">in all patients by Inductively Coupled Plasma Mass Spectroscopy Method(ICP–MS).<o:p></o:p></span></p>
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal"><span style="color:black;background:white">RESULTS:</span></b>On Hematological <span style="mso–fareast–font–family:"Times New Roman";mso–fareast–theme–font:minor–fareast;
color:black;background:white">evaluations, </span>40% showed abnormal findings which revealed Eosinophilia(24%), leucocytosis (12%), lymphocytosis and dimorphic anemia in each patient.<span style="mso–fareast–font–family:"Times New Roman";
mso–fareast–theme–font:minor–fareast;background:white"> On Spirometry,mild, moderate and severe restrictionwere observed in 14%, 18% and 20% <span style="mso–spacerun:yes"> </span>respectively.</span> On evaluation of other systems, LFT, RFT and ECG all showed no abnormalities.<span lang="EN–IN" style="color:black;mso–themecolor:text1;mso–ansi–language:EN–IN">In our study, no abnormal levels of blood and urine chromium were made out. Only traces of chromium in ranges of 0.05 to 3 </span><span style="mso–fareast–font–family:
"Times New Roman";mso–fareast–theme–font:minor–fareast;color:black;mso–themecolor:
text1;background:white">µg/L</span><span lang="EN–IN" style="color:black;
mso–themecolor:text1;mso–ansi–language:EN–IN"> was noticed in most patients. <o:p></o:p></span></p>
Keywords: contact dermatitis, serum chromium, urine chromium