Original Research Paper Orthopaedics

STUDY TO EVALUATE THE OUTCOME OF THE DISTAL FEMUR FRACTURES TREATED WITH LOCKING COMPRESSION PLATE USING MODIFIED SWASHBUCKLER APPROACH

Kishore Raichandani Sanjay Garhwal Raunak Surana Abhinav Bhardwaj Ashok Singhvi Surbhi Raichandani

Abstract

<p> <b><span lang="EN–IN" style="font–size:12.0pt;line–height:107%;font–family:"Times New Roman",serif;
mso–fareast–font–family:"Times New Roman"">INTRODUCTION</span></b></p>
<p class="MsoNormal"><span lang="EN–IN" style="font–size:12.0pt;line–height:107%;
font–family:"Arial",sans–serif;mso–fareast–font–family:Arial"> </span></p>
<p class="MsoNormal"><b><i><span lang="EN–IN" style="font–size:9.0pt;line–height:107%;font–family:
"Times New Roman",serif;mso–fareast–font–family:"Times New Roman"">The pattern of distal femur fractures is changing from simple extra–articular to intra– articular type. In high energy trauma, the problem of restoring the function in a destroyed knee joint persists. Modified swashbuckler approach provide excellent exposure of inter–condylar fractures which give easy reduction of condylar fractures and better functional outcomes.<o:p></o:p></span></i></b></p>
<p class="MsoNormal"><b><span lang="EN–IN" style="font–size:12.0pt;line–height:107%;font–family:"Times New Roman",serif;
mso–fareast–font–family:"Times New Roman"">MATERIAL AND METHODS<o:p></o:p></span></b></p>
<p class="MsoNormal"><b><i><span lang="EN–IN" style="font–size:9.0pt;line–height:107%;font–family:
"Times New Roman",serif;mso–fareast–font–family:"Times New Roman"">Between 2014 to 2016, we treated 40 patients of distal femur fractures with locking compression plate using modified swashbuckler approach. All patients were followed up for a minimum period of 12 months and evaluated using Neer s criteria.<o:p></o:p></span></i></b></p>
<p class="MsoNormal"><b><span lang="EN–IN" style="font–size:12.0pt;line–height:107%;font–family:"Times New Roman",serif;
mso–fareast–font–family:"Times New Roman"">RESULTS<o:p></o:p></span></b></p>
<p class="MsoNormal"><b><i><span lang="EN–IN" style="font–size:9.0pt;line–height:107%;font–family:
"Times New Roman",serif;mso–fareast–font–family:"Times New Roman"">34 patients (85%) showed radiological union within 16 weeks. 20% cases had post–operative complications which include superficial infection. At end of 12 months 75% cases had good or excellent results and 50% patients returned to their pre injury functional level.<o:p></o:p></span></i></b></p>
<p class="MsoNormal"><b><span lang="EN–IN" style="font–size:12.0pt;line–height:107%;font–family:"Times New Roman",serif;
mso–fareast–font–family:"Times New Roman"">CONCLUSION<o:p></o:p></span></b></p>
<p class="MsoNormal"><b><i><span lang="EN–IN" style="font–size:9.0pt;line–height:107%;font–family:
"Times New Roman",serif;mso–fareast–font–family:"Times New Roman"">Modified swashbuckler approach provide excellent exposure of intra–articular fractures and locking compression plate provide stable fixation through multiple points of fixed plate –to– screw contact. <o:p></o:p></span></i></b></p>

Keywords: Distal femur fractures, Modified swashbuckler approach, Locking compression plate, Neer’s criteria