Original Research Paper Plastic Surgery

PROSPECTIVE STUDY OF CLOSURE OF COMPOUND WOUNDS WITH STAINLESS STEEL WIRES

Dr. Pokkula Ramesh Dr. Challuri Anita Dr. Arige Subodh kumar Dr. Erugurala Mahendar Dr. Valluri Mukesh Krishna

Abstract

<p> </p>
<p class="MsoNormal" style="line–height:200%;tab–stops:84.0pt"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
text–transform:uppercase">Introduction:<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">Chronic <span style="mso–spacerun:yes"> </span>compound wounds<span style="mso–spacerun:yes"> </span>are<span style="mso–spacerun:yes"> </span>common due to increase in<span style="mso–spacerun:yes"> </span>trauma. Wound closure using external fixators is described , <span style="mso–spacerun:yes"> </span>bringing the<span style="mso–spacerun:yes"> </span>inherent skin properties into play, and here 24 guage<span style="mso–spacerun:yes"> </span>Stainless Steel<span style="mso–spacerun:yes"> </span>wire<span style="mso–spacerun:yes"> </span>was used<sup> </sup>. <o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">AIM: <o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif""><span style="mso–spacerun:yes"> </span>To study the effectiveness of <span style="mso–spacerun:yes"> </span>wound closure in compound<span style="mso–spacerun:yes"> </span>chronic wounds using 24 guage<span style="mso–spacerun:yes"> </span>Stainless Steel<span style="mso–spacerun:yes"> </span>wire. <o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">RESULTS:<span style="mso–spacerun:yes"> </span>Study was done on<span style="mso–spacerun:yes"> </span>15 males, and five females , aged between 10 to 60 years, with wounds<span style="mso–spacerun:yes"> </span>on leg, varying in sizes between 15 and 96 square centimeters. The wound closure was achieved<span style="mso–spacerun:yes"> </span>in two weeks. Two complications of wire cutting, were addressed by skin grafting<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%;tab–stops:121.5pt"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">MATERIAL AND METHODS:<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%;tab–stops:121.5pt"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif""><span style="mso–spacerun:yes"> </span>Prospective<span style="mso–spacerun:yes"> </span>study was done using 24 guage Stainless steel wire on<span style="mso–spacerun:yes"> </span>20 <span style="mso–spacerun:yes"> </span>patients<span style="mso–spacerun:yes"> </span>in <span style="mso–spacerun:yes"> </span><span style="mso–spacerun:yes"> </span>Gandhi hospital<span style="mso–spacerun:yes"> </span>in<span style="mso–spacerun:yes"> </span>2017. <o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%;tab–stops:121.5pt"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif""><span style="mso–spacerun:yes"> </span>Under Local<span style="mso–spacerun:yes"> </span>anesthesia , two 24 guage wires were introduced in the sub–dermal plane,<span style="mso–spacerun:yes"> </span>twisting was done on alternate days to narrow down the <span style="mso–spacerun:yes"> </span>wound size, till approximation.<span style="mso–spacerun:yes"> </span><o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">DISCUSSION:<span style="mso–spacerun:yes"> </span>Skin has inherent properties like elasticity, stress relaxation and creep.<span style="mso–spacerun:yes"> </span>Stainless steel wire, was used towards achieving wound closure by expanding the skin, and in all<span style="mso–spacerun:yes"> </span>local anaesthesia, was used on out–patient basis, needing lesser time<span style="mso–spacerun:yes"> </span>than the flap cover . The<span style="mso–spacerun:yes"> </span>approximation time was less than three weeks. <o:p></o:p></span></p>

Keywords: Compound wound, Wound closure, Stainless steel wire, skin properties, wire twisting