Volume : IX, Issue : III, March - 2020

AN IN VITRO STUDY TO EVALUATE THE TEAR STRENGTH OF AUTOCLAVABLE PVS, SMART WETTING PVS AND CONDENSATION SILICONE AND COMPARE THEM UPON AUTOCLAVING AND DISINFECTION.

Dr. Garima Gothwal, Dr. Hemant Kumar Sharma, Dr. Kusum Singh, Dr. Richa Sengar

Abstract :

Aim: The tear strength of three different types of elastomeric impression materials was measured after disinfection and sterilization. Material and Method: Dumb–bell shaped Tear strength specimens were prepared according to ISO 34–1 standardization. Ninety samples were prepared followed by disinfection and sterilization and tested with trouser piece method on Instron universal testing machine at a speed of 10 mm/min. One way ANOVA, followed by Tukey post hoc test was used for statistical analysis. Results: No significant difference was found when AFFINIS, SPEEDEX and AQUASIL were compared individually. When materials were compared with each other significant difference was present, highest AQUASIL while SPEEDEX and AFFINIS almost alike. Conclusion: It was concluded that tear strength of AQUASIL was the highest. Disinfection and autoclaving had no significant influence on the three materials and showed adequate tear strength.

Keywords :

Article: Download PDF    DOI : 10.36106/ijsr  

Cite This Article:

AN IN VITRO STUDY TO EVALUATE THE TEAR STRENGTH OF AUTOCLAVABLE PVS, SMART WETTING PVS AND CONDENSATION SILICONE AND COMPARE THEM UPON AUTOCLAVING AND DISINFECTION., Dr. Garima Gothwal, Dr. Hemant Kumar Sharma, Dr. Kusum Singh, Dr. Richa Sengar INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-9 | Issue-3 | March-2020


Number of Downloads : 121


References :