Volume : VII, Issue : IX, September - 2018

Calculate the temperature of electron for TiO2 plasma induced by pulse laser deposition

Hasan Ali Tawfeeq

Abstract :

In this work; titanium dioxide (TiO2) were faicated by pulsedlaser ablation (PLA). Theelectron temperature was calculated byreading the data of I–V curve of Langmuir probewhich wasemployed as a diagnostic technique for measuring plasma properties.Pulsed Nd:YA Glaser was used for measuring the electrontemperature of TiO2 plasmaplume under vacuum environment withvarying both pressure and axial distance from thetarget surface. Theelectron temperature has been measured experimentally and theeffects of each of pressure and Langmuir probe distance from thetarget were studied. An inverse relationship between electrontemperature and both pressure and axial distance was observed.

Keywords :

Article: Download PDF   DOI : 10.36106/ijsr  

Cite This Article:

Hasan Ali Tawfeeq, Calculate the temperature of electron for TiO2 plasma induced by pulse laser deposition, INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-9 | September-2018


Number of Downloads : 268


References :