Perfusion Index derived from a Pulse Oximeter as a Predictor of Hypotension following Subarachnoid Block (SAB) for below Umbilical Surgeries.

Dr. Ankita Gupta, Dr. Anuj Dubey, Dr. Anupam Pandey, Dr. Mahima Batra, Dr. Sanjay P. Dave

Abstract :

Perfusion Index (PI) is a relatively new parameter tried for predicting hypotension . This study aimed at investigating correlation between baseline PI and incidence of hypotension following Sub–arachnoid block (SAB) . In this prospective & observational study , patients were divided into 2 groups on the basis of baseline PI. Group I with PI < 3.5 and Group II PI > 3.5. SAB performed with 15 mg of 0.5% (H) bupivacaine at L3–L4 inter–verteal space. The incidence of hypotension in group I (PI< 3.5) was 10.71% compared to 68.97% in group II (PI > 3.5). There was significant correlation between baseline PI and number of episodes of hypotension . The ROC (Reciever Operating Characteristic) curve analysis revealed that baseline PI was suitable for detecting patients at risk for hypotension . For predicting hypotension , perfusion index (PI) can be used as a tool in patients undergoing below umbilical surgeries for SAB . Patients with baseline PI >3.5 have higher chances of developing hypotension than patients with PI <3.5.

Keywords :

Article: Download PDF    DOI : 10.36106/ijsr  

Cite This Article:

PERFUSION INDEX DERIVED FROM A PULSE OXIMETER AS A PREDICTOR OF HYPOTENSION FOLLOWING SUB-ARACHNOID BLOCK (SAB) FOR BELOW UMBILICAL SURGERIES., DR.ANKITA GUPTA, DR.ANUJ DUBEY, DR.ANUPAM PANDEY, DR.MAHIMA BATRA, DR.SANJAY P.DAVE INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-8 | Issue-10 | October-2019