Volume : III, Issue : XI, November - 2014

Trying triangle in silicon sling suspension surgery in ptosis

Dr. Gazala Mansuri, Dr. Nitin Trivedi

Abstract :

Aim: To compare pentagonal pattern of silicon sling suspension with triangular pattern. Methods: 37 eyelids of 31 patients with ptosis, 6 patients operated bilaterally where18 eyelids undergone pentagonal pattern and 19 eyelids with triangular pattern. Successful surgical results were judged by lid level, lid symmetry and lid contour during the follow up period of 9 months. Result: No difference in functional success, ptosis recurrence, or change in MRD I was noticed in both the groups. No patient was seen with complications like exposure keratitis, granuloma formation. 4 eyelids, 2 in each group required re–surgery during the follow up period. Conclusion: The use of triangular pattern of silicone rod frontalis suspension surgery for ptosis repair is equally effective, with few complications, easily adjustable in case of recurrence or overcorrection and better cosmesis with triangular pattern.

Keywords :

Article: Download PDF   DOI : 10.36106/ijsr  

Cite This Article:

Dr. Gazala Mansuri,Dr. Nitin Trivedi Trying triangle in silicon sling suspension surgery in ptosis International Journal of Scientific Research, Vol : 3, Issue : 11 November 2014