Jet impingement cooling of triangular ribbed surface with bottom exit grill ( Category–Engineering )
Dr. M. T. Bhoite, Kartik Jujare, Sayali Wable
Abstract :
Jet impingement is a technique used widely for electronics cooling. The parameters of importance are Reynolds number, geometry configuration of the jet impingement. In the present work, a geometrical configuration of triangular ribbed surface is chosen, conditioned air is supplied as jet from the top while the bottom exit grills are used for exhaust of the spent air. The analysis is carried out using Computational Fluid Dynamics based analysis using FLUENT software and is validated against the experimental results.
Keywords :
Article:
Download PDF
DOI : 10.36106/ijar
Cite This Article:
Dr. M.T. Bhoite,Kartik Jujare,Sayali Wable Jet impingement cooling of triangular ribbed surface with bottom exit grill ( Category-Engineering ) Indian Journal of Applied Research, Vol.III, Issue.II February 2013
Number of Downloads : 737
Dr. M.T. Bhoite,Kartik Jujare,Sayali Wable Jet impingement cooling of triangular ribbed surface with bottom exit grill ( Category-Engineering ) Indian Journal of Applied Research, Vol.III, Issue.II February 2013